Omron STC-MBS500U3V USB 3.0 2/3" Sony IMX264 CMOS, 5 MP, Monochrome, C Mount Camera
The Omron STC-MBS500U3V USB 3.0 camera delivers 5.1 MP resolution using the Sony IMX264 CMOS sensor with global shutter. Key features include 2448 x 2048 resolution, 35.8 fps output, advanced noise control, programmable gamma, ROI adjustments, and GenICam/USB3 Vision® compliance. Ideal for industrial and scientific precision imaging.
NDAA CompliantThe Omron STC-MBS500U3V USB 3.0 monochrome camera offers precision imaging performance, powered by the Sony IMX264 2/3” 5.1-megapixel CMOS sensor. With a progressive scan global shutter, it ensures distortion-free capture of fast-moving subjects. The active pixel array delivers 2448 (H) x 2048 (V) resolution, while each pixel measures 3.45 µm, providing exceptional detail and clarity.
This versatile camera supports adjustable frame rates of up to 35.8 fps at 8/10/12-bit depths, including packed modes for optimized data transfer. Advanced noise control minimizes signal disruption, achieving ≤3 LSBs for 8-bit and ≤48 LSBs for 12-bit outputs at 0 dB gain. A broad exposure time range, spanning from 27.2 microseconds to 56 seconds, accommodates diverse lighting scenarios.
Key imaging enhancements include programmable gamma (0.1–4.0), pixel defect correction for up to 64 points, and flexible region of interest (ROI) adjustment with step-specific offsets. Gain controls feature analog (0–20.8 dB) and digital (0–6 dB) configurations for tailored sensitivity. Binning and decimation options refine image scaling, while flip modes (horizontal, vertical, or both) expand usability.
Engineered for streamlined integration, the Omron STC-MBS500U3V supports USB3 Vision® 1.0.1 and GenICam protocols over a USB 3.0 Micro B interface, ensuring compatibility with modern vision systems. GPIO interfaces provide flexible I/O control, while operational modes include free-run and multiple triggering options. With a low typical power consumption of 2.8 W at +5V input, this camera is ideal for demanding industrial and scientific applications.
Features:
- Sensor: Sony IMX264 2/3” 5.1 MP Monochrome CMOS
- Shutter: Global for distortion-free capture
- Resolution: 2448 (H) x 2048 (V) with 3.45 µm pixel size
- Frame Rate: Up to 35.8 fps at 8/10/12-bit outputs
- Interface: USB 3.0 with USB3 Vision® and GenICam compliance
- Advanced Imaging: ROI adjustment, pixel defect correction, binning, and gamma control
- Triggering Modes: Free-run, edge-preset, pulse-width, and start/stop
- Power Consumption: Low power (2.8W typical)
Applications:
- Industrial machine vision
- Scientific imaging and analysis
- Precision measurement systems
- High-speed object tracking
- Automated optical inspection (AOI)
| Image Sensor | 2/3” 5.1M Progressive Monochrome CMOS (Sony: IMX264) |
| Shutter Type | Global |
| Active Picture Element | 2448 (H) x 2048 (V) |
| Cell Size | 3.45 (H) x 3.45 (V) µm |
| Sync System | Free run, External trigger (Hardware, Software) |
| Maximum Frame Rate (Full Scan) | - |
| -8Bit Output | 35.8 fps |
| -10Bit Output | 35.8 fps |
| -10bit Packed output | 35.8 fps |
| -12Bit Output | 35.8 fps |
| -12bit Packed output | 35.8 fps |
| ADC bit width | 10bit / 12bit |
| Video Format | 8/10/12 bit output (Support packed on 10bit, 12bit) |
| Noise Level | - |
| -8Bit Output | ≤ 3 LSBs (Gain 0 dB) |
| -10bit / 10bit Packed Output | ≤ 12 LSBs (Gain 0 dB) |
| -12bit / 12bit Packed Output | ≤ 48 LSBs (gain 0 dB) |
| Sensitivity | 380 Lux |
| Exposure Time | - |
| -8Bit Output | 27.2μseconds to 56 seconds |
| -10Bit Output | 27.2μseconds to 56 seconds |
| -10bit Packed output | 27.2μseconds to 56 seconds |
| -12Bit Output | 27.2μseconds to 56 seconds |
| -12bit Packed output | 27.2μseconds to 56 seconds |
| Gain | - |
| -Analog (Gain) | 0 to 20.8 dB |
| -Digital (Gain) | 0 to 6 dB |
| Black Level | - |
| -8Bit Output | 0 to 31 |
| -10bit / 10bit Packed Output | 0 to 127 |
| -12bit / 12bit Packed Output | 0 to 511 |
| White Balance | N/A |
| ROI (AOI) | Horizontal: 64 to 2448 (2432 on Packed) / Vertical: 32 to 2048 Adjustable Steps for offset: 16 pixels in horizontal direction (64 pixels on Packed) / 4 lines in vertical direction Adjustable Steps for offset: 4 pixels in horizontal direction / 4 lines in vertical direction |
| Gamma | Gamma Table =0.1 to 4.0, Default = 1.0 |
| Binning | Individual x2 Horizontal, Vertical Binning / OFF (Horizontal: Average, Vertical: Addition) *8 |
| Decimation | Individual x2 Horizontal, Vertical Decimation |
| Image Flip | Horizontal / Vertical / Horizontal and Vertical / OFF |
| Pixel Defect Correction | Up to 64 points |
| Auto Image Control | - |
| -Auto Exposure | Support (Default: Fix 27.5 mseconds) |
| -Auto Gain | Support (Default: Fix x1) |
| -Auto White Blance | N/A |
| Operational Mode | Free-run/ Edge-preset Trigger/ Pulse width Trigger/ Start Stop Trigger |
| User Setting Mode | Support |
| Communication | Via USB3.0 bus |
| Interface | USB3.0 Super speed (USB3.0 Micro B) |
| Protocol | USB3 Vision® 1.0.1, GenICam Standard Version (SFNC 2.2, PFNC 2.0) compliant and Sentech’s unique protocol (on Normal SDK, Trigger SDK) |
| Lens Mount | C Mount |
| Input/Output | Three GPIO, One Camera Hardware Reset |
| Power | - |
| Input Voltage | +5V(typ.) (This conforms to the USB standard) |
| Consumption | Max: 3.4W, Typ: 2.8W |