The National Instruments PCI-1426 and NI PCIe-1427
are low-cost Camera Link image acquisition boards
designed for machine vision and scientific imaging
applications that require high-resolution digital
imaging with simple cabling. Both boards work
with any base-configuration Camera Link camera
and include a simple 15-pin D-Sub connector for
camera triggering and system integration. A list
of applicable Camera Link cameras can be found
on the Camera Advisor.
Image acquisition for base-configuration
Camera Link cameras
Isolated digital I/O
Onboard programmable region of
interest and image binarization
Available for PCI and PCI Express
Includes Vision Acquisition software
Specifications Typical at 25° C, unless
otherwise stated.
External
Connections
Trigger
sense
TTL
Trigger
polarity
Programmable (positive or negative)
Pixel
clock
Camera Link compatible
Enables
Camera Link compatible
Control
signal
Camera
Link compatible
Video
data
Camera Link compatible
Clocks
Pixel
clock frequency range
20 to 50 MHz
PCI
Master Performance
Sustained
100 MB/s
Onboard
Memory
PCI
16 MB
Power
Requirements
+5
VDC
1.5 A
+12
VDC
24 mA
-12
VDC
20 mA
Physical
Dimensions
PCI
10.7 by 17.5 cm (4.2 by 6.9 in.)
Environment
Operating
temperature
0 to 55 °C
Storage
temperature
-20
to 70 °C
Relative
humidity
5 to 90%, noncondensing
MTBF
544,562
h at 25 °C
Emissions
EN
55011:1991 Group 1 Class A
at 10 m FCC Class A at 10 m